  1.     SECTION 05515
  2.  
  3.     EXIT LADDER DEVICES
  4. NOTE ** This section is based on products manufactured by Jomy Safety Products, Inc., at the following address:
  5. NOTE **      1728 16th St.
  6. NOTE **      Suite 201
  7. NOTE **      Boulder, CO  80302
  8. NOTE **      Tel:  303-440-9007 (800-255-2591)
  9. NOTE **      Fax:  303-440-9091
  10. NOTE ** 
  11. NOTE ** The Jomy Safety Ladder is intended for emergency exit or rescue, or for mechanical equipment access.  Looking like an ordinary drainpipe when closed, a quarter turn of a handle deploys a 2-foot-wide industrial strength ladder with slip-resistant rungs and a safety rail.  A Jomy balcony is available to supplement access to the ladder where required.
  12. NOTE ** 
  13. NOTE ** SECTION 05515 - EXIT LADDER DEVICES, Copyright 1998, The Architect's Catalog, Inc.
  14.  
  15. PART 1    GENERAL
  16.  
  17. 1.1    SECTION INCLUDES
  18. NOTE ** Delete items below not required for project.
  19.  
  20.     A.    Retractable exit ladders for use as supplemental escape devices.
  21.  
  22.     B.    Retractable ladder devices to provide access to mechanical equipment.
  23.  
  24.     C.    Access balconies.
  25.  
  26. 1.2    RELATED SECTIONS
  27. NOTE ** Delete any sections below not relevant to this project;  add others as required.
  28.  
  29.     A.    Section 03300 - Cast-In-Place Concrete.
  30.  
  31. 1.3    REFERENCES
  32. NOTE ** Delete references from the list below that are not actually required by the text of the edited section.
  33.  
  34.     A.    Evaluation Reports;  Building Officials and Code Administrators International, Inc. (BOCA).
  35.  
  36.     B.    Evaluation Reports;  International Conference of Building Officials (ICBO).
  37.  
  38.     C.    Uniform Building Code;  International Conference of Building Officials (ICBO).
  39.  
  40.     D.    Uniform Fire Code;  International Conference of Building Officials (ICBO).
  41.  
  42.     E.    Uniform Mechanical Code;  International Conference of Building Officials (ICBO).
  43.  
  44.     F.    Uniform Building Code Standards;  International Conference of Building Officials (ICBO).
  45.  
  46.     G.    Underwriters Laboratories Inc. (UL).
  47.  
  48. 1.4    SUBMITTALS
  49.  
  50.     A.    Submit under provisions of Section 01300.
  51.  
  52.     B.    Product Data:  Provide manufacturer's standard details and catalog data demonstrating compliance with referenced standards.  Provide installation instructions.
  53.  
  54.     C.    Shop Drawings:  
  55.         1.    Submit drawings showing overall height of ladders, and location of deployment handles in relation to floor elevations, window sills, and railings.
  56. NOTE ** Delete the following if not required.
  57.         2.    Submit drawings illustrating layout and anchorage of balconies.
  58.  
  59.     D.    Warranty:  Submit manufacturer's standard warranty.
  60.  
  61. 1.5    DELIVERY, STORAGE, AND HANDLING
  62.  
  63.     A.    Store products indoors and protect from moisture, construction traffic, and damage.
  64.  
  65. 1.6    WARRANTY
  66.  
  67.     A.    Manufacturer's standard warranty against defects in materials and workmanship;  10 year period.
  68.  
  69.  
  70. PART 2    PRODUCTS
  71.  
  72. 2.1    MANUFACTURER
  73.  
  74.     A.    Provide products fabricated by Jomy Safety Products, Inc.;  1728 16th St.;  Suite 201;  Boulder, CO  80302; ASD. Tel: 303-440-9007 (800-255-2591), Fax: 303-440-9091.
  75.  
  76. 2.2    MATERIALS
  77.  
  78.     A.    Stiles:  Extruded aluminum, 6063-T6 alloy.
  79.  
  80.     B.    Rungs:  Extruded aluminum, 6005-T5 and 6005-T6 alloy.
  81.  
  82.     C.    Brackets:  6063-T6 aluminum alloy.
  83.  
  84.     D.    Balcony:  6063-T6 aluminum alloy.
  85.  
  86.     E.    Pivot Pins, Springs, Masonry Bolts, Fasteners, and Base Plates:  Stainless steel.
  87.  
  88. 2.3    LADDERS
  89.  
  90.     A.    General:  
  91.         1.    Retractable ladder with deployment handles at each point of access;  stainless steel counterbalance springs;  requiring less than five pounds of force to deploy.
  92.         2.    Maintenance-free, aluminum and stainless steel construction.
  93.         3.    Support 1000 lbs. per rung individually;  200 lbs. per 6 feet of length simultaneously.
  94.         4.    Ground support of gravity loads;  building wall support for lateral stability.
  95.         5.    Provide deployment handle at each access level.
  96.  
  97.     B.    Certifications:
  98.         1.    Exit ladder device:  UBC Std. 33-3.
  99.         2.    Supplementary means of egress:  Underwriters Laboratories Inc.
  100.         3.    Supplemental escape device:  Accepted under BOCA and ICBO evaluation reports for use up to 30 feet under appendices of Uniform Building Code and Uniform fire Code.
  101.         4.    Mechanical equipment ladder:  Accepted under ICBO evaluation reports in compliance with Uniform Mechanical Code.
  102.  
  103.     C.    Provide dual safety rails at ladders with access from both sides.
  104.  
  105.     D.    Provide reinforcement channel where ladders extend beyond wall support, such as at parapets and roof tops, or where ladder spans open areas in excess of 5 feet between attachment points.
  106.  
  107.     E.    Shop fabricate and assemble to maximum extent practicable for installation on-site with minimal labor.
  108. NOTE ** Delete the following Article if balconies are not required.
  109.  
  110. 2.4    BALCONIES
  111. NOTE ** Delete 1 of the 2 following paragraphs.
  112.  
  113.     A.    Provide aluminum balconies at each access level.
  114.  
  115.     B.    Provide aluminum balconies at locations indicated on the drawings.
  116. NOTE ** Delete 2 of the following 3 paragraphs.
  117.  
  118.     C.    Size:  24 x 42 inches, nominal.
  119.  
  120.     D.    Size:  38 x 42 inches, nominal.
  121.  
  122.     E.    Size:  Custom size as indicated on the drawings.
  123.  
  124.     F.    42-inch rail 2 sides, restraining chain 1 side.
  125.  
  126.     G.    Capacity:  1000 lbs. per sq. meter.
  127.  
  128. 2.5    ACCESSORIES
  129.  
  130.     A.    Provide brackets, spacers, etc., necessary for a complete installation.
  131. NOTE ** When used for access, the lower handle is removed and locked off to prevent unauthorized access.
  132. NOTE ** 
  133. NOTE ** Delete the following paragraph if not required.
  134.  
  135.     B.    Provide removable deployment handle at lower access point;  provide locking hub and padlock.
  136. NOTE ** Delete 1 or both of the 2 following paragraphs if not required.  Bolts for securement to masonry are provided as standard items, specified above under Materials.
  137.  
  138.     C.    Fasteners for securement to wood construction:  Stainless steel lag bolts;  3/8-inch diameter, 4-inch minimum embedment.
  139.  
  140.     D.    Fasteners for securement to steel construction:  Stainless steel bolts, nuts, and washers; 3/8-inch diameter.
  141.  
  142. 2.6    FINISHES
  143. NOTE ** Delete 1 of the 2 following paragraphs.  Shop painting, below, is special order.  Units may be field painted, if desired.
  144.  
  145.     A.    Aluminum:  Clear anodized.
  146.  
  147.     B.    Manufacturer's standard shop-applied enamel.
  148.         1.    Color:  As selected from manufacturer's standards.
  149.         2.    Color:  Match paint sample supplied by Architect.
  150.  
  151.  
  152. PART 3    EXECUTION
  153.  
  154. 3.1    EXAMINATION
  155.  
  156.     A.    Verify that wall surfaces to receive units are complete and approved prior to installing work of this section.
  157.  
  158. 3.2    FOOTING
  159.  
  160.     A.    Install concrete footing in accordance with manufacturer's requirements, and in compliance with Section 03300.
  161.  
  162. 3.3    INSTALLATION
  163.  
  164.     A.    Install components in strict compliance with manufacturer's instructions.
  165.  
  166. 3.4    ADJUST AND CLEAN
  167.  
  168.     A.    Adjust operating parts for smooth deployment and storage.
  169.  
  170.     B.    Remove scraps and debris;  leave project site in clean and orderly condition.
  171.  
  172.     C.    Instruct the Owner's representative in proper operation.
  173.  
  174.  
  175.     END OF SECTION
  176. ??
  177.  
  178.  
  179.  
  180.  
  181.  
  182.  
  183.  
  184.  
  185.  
  186.     05515-1